Case study | Heritage documentation

A measured record of the Last Supper Museum.

A historic building in Douglas, Arizona, with a restoration under way and no drawings to work from. We scanned all 15,497 SF and drew the entire building for the Engineer of Record.

Section through the building at the skylight, cut from the color laser scan: roof trusses, floors and basement, with level markers and dimensions
Section at the skylight, looking south: cut from the color laser scan, with levels and dimensions.

Location

Douglas, Arizona

Building

15,497 SF on three levels

Scan

165 stations in full color, measured to USIBD LOA 40

Our role

Laser scan, existing conditions documentation, engineering and contractor coordination

The building, lengthwise

Building section cut along the length of the building from the color laser scan: roof framing, upper floor, ground floor and basement, with levels
Building section from the set, cut from the color laser scan along the length of the building: roof framing, upper floor, ground floor and basement.

The challenge

The museum had begun restoring its building. Its conservators were working from photographs and what they could see, and there were no drawings of the structure. The roof framing had to be assessed so that remediation crews could work on the roof safely.

Our approach

We scanned all three levels from 165 stations in full color and registered the scans into one point cloud. From it we drew the entire building for the Engineer of Record. Then we worked with the Engineer of Record and the contractor on the roof. We covered the framing as it stands, where it falls short, and how to support it while crews work on it.

What the scan showed

The roof is framed with site-built parallel chord trusses of 2x8 lumber at 16 inches on center. They are pocketed into the masonry walls and pitched to form a butterfly roof. The Engineer of Record identified three areas where that framing is unsupported or overspanned.

A site-built parallel chord roof truss cut from the color laser scan, with its spans and depth dimensioned
The typical truss, cut from the scan and dimensioned: 48 feet 3 1/2 inches end to end.

What we drew

  • The entire building, drawn as existing conditions for the Engineer of Record.
  • The existing roof framing plan and a building section, drawn over the scan imagery.
  • Sections at the skylight, cut from the scan in two directions.
  • The typical truss configuration, dimensioned.
  • The three areas the Engineer of Record identified, marked on the framing plan.
  • A temporary shoring layout for those areas, so crews could work on the roof safely.

Where it stands

The roof remediation is complete: the roof was waterproofed and flashed. Substructure concerns remain that need engineering analysis, and the bearing walls need stabilization. The owners are pursuing Brownfield grants for that structural repair.

Engineering by the Engineer of Record.

From the set

Existing roof framing plan drawn over the color laser scan: closely spaced trusses seen from above, with three areas outlined in blue
Existing roof framing plan from the set, drawn over the color laser scan. The three areas outlined in blue are those the Engineer of Record identified as unsupported or overspanned.
Temporary roof shoring layout: three hatched areas inside the building outline with posts, beams and dimensions
Temporary shoring layout from the set: posts and beams under the three areas, dimensioned from the walls.

Select a drawing to open it full size.

All projects

Your project could be next.

Tell us what you're building. We reply within 1 business day with next steps.

Planning a remodel, addition or new home?

Get The Homeowner's Survival Guide to Construction Projects: 15 pages on keeping the design decisions on your project in your hands. Free PDF. No sign-up.